adviceLUNA / TRQer Support

[Error]OCD register setup time-out occurred

[Scope]
ARM

[Error message]
ICE Error No.f2d: OCD register setup time-out occurred.

[Cause]
This error is output when access to OCD resources cannot be made via JTAG successfully.

[Workaround]
- Choose [MPU]-[MPU-Specific Settings] from the menu bar of the microVIEW-PLUS. Open the [User System] tab and check if MPU type is set up correctly matching with an MPU of a user system.
- Choose [MPU]-[MPU-Specific Settings] from the menu bar of the microVIEW-PLUS. Open the [Daisy Chain] tab and check if the number of Bypass Bit and ETB Bypass are set up correctly matching with those of a user system.

 

Please cooperate with the questionnaire

Was this answer stood to the visitor's role?

 

           

Return to search