adviceLUNA / TRQer Support
[Error]Select "Don’t Care" for a data size when FT is specified.
[Scope]
ARM
[Error message]
ICE Error No.fc4: Select "Don’t Care" for a data size when FT is specified.
[Cause]
This error is output when MPU status FT is specified for OCD break and a data size is also specified.
[Workaround]
- Specify a data size Don’t Care when you specified FT for MPU status.
ARM
[Error message]
ICE Error No.fc4: Select "Don’t Care" for a data size when FT is specified.
[Cause]
This error is output when MPU status FT is specified for OCD break and a data size is also specified.
[Workaround]
- Specify a data size Don’t Care when you specified FT for MPU status.
Please cooperate with the questionnaire
Was this answer stood to the visitor's role?