[Function/Specification] Break-rotational-display of the countable break

[Function/Specification] Break-rotational-display of the countable break [Information]
The break-rotational-display of the countable break can be checked from [View] [Break list] of microVIEW-PLUS menu.
The number of breaks are shown as “The number of break/The specified number" when the countable break is set.
The number of break is automatically cleared when a countable break occurs after the specified number of break is occurred.
Therefore, please note that it looks the counting is stopped with “0/the specified number" display when the countable break occurs, but it does not stop actually.

 