adviceLUNA / TRQer Support

[Error]Time-out waiting for write buffer drain to complete.

[Scope]
ARM

[Error message]
ICE Error No.f2f: Time-out waiting for write buffer drain to complete.

[Cause]
This error is output when draining write buffer is not completed when a user system is attached or when a break occurs.
Specified MPU type or AHB/AP offset may bewrong.

[Workaround]
- Choose [MPU]-[MPU-Specific Settings] from the menu bar of the microVIEW-PLUS.
Open the [User System] tab and check if "MPU type" is set up correctly matching with an MPU of a user system.
- Choose [MPU]-[MPU-Specific Settings] from the menu bar of the microVIEW-PLUS.
Open the [CoreSight] tab and check if "AHB/APB offset" is set up correctly.
If this value is 0xffffffff(auto adjust), please set the correct offset address.

 

Please cooperate with the questionnaire

Was this answer stood to the visitor's role?

 

           

Return to search