adviceLUNA II Support

[Question] Cores and peripheral devices are connected by daisy chain. How to set it?

[Answer]
Set the daisy chain at the daisy chain tab on the MPU-specific settings dialog box.
Start up the project file and microVIEW-PLUS without resetting it. Set the daisy chain at MPU-specific setting dialog box.

[Details]
Connect the core to debug by bypassing the cores or peripheral devices not to debug.
¡¦For the number of bypass TAP, set the bypass register bit length (the number of TAP).
1 bit for one core, or one peripheral device
¡¦ For the number of IR register bit, set the IR instruction bit length.
For ARM7/9 core, set 4 bit for IR instruction bit length.
For ARM11 core, set 5 bit for IR instruction bit length.

If more than 3 cores are daisy chained, set the total number of BYPASS bit by partitioning the core into pre-stage, mid-stage, and post-stage. (Set the core to debug to mid-stage.)

For details, see Section 20.1.5 ¡ÈDaisy chain" of microVIEW-PLUS User¡Çs Manual (MPU-Specific Edition) (H2X600_eng.pdf).
Note

 

Please cooperate questionaire cooperation

Was this answer stood to the visitor's role?

 

           

return to a page