[Tips] Notes for when doing hot plug connection after exiting debug tool of Xilinx (XMD)

[Scope of application]
adviceLUNAII / adviceLUNA
H2X600 / SLX600 / SLX621 / AQ737
Zynq / ZYNQ7000

[Information]
If you connect adviceLUNA/LUNA II by hot plug without turning off the user system power after exiting a system verification debug tool of Xillinx, Xilinx Microprocessor Debugger(XMD), depending on the revision of Vivado Design Suite, a design development environment of Xilinx, you will need to issue the following command from microVIEW-PLUS after the hot plug.

¡¡For Vivado 2013.4 or earlier
¡¡¡¡¡¡You do not issue a command after connecting adviceLUNA/LUNA II by hot plug.
¡¡For Vivado 2014.1 or later
¡¡¡¡¡¡Issue the following command from a command window of microVIEW-PLUS after connecting adviceLUNA/LUNA II.
¡¡¡¡¡¡¡¡¡¡mem l dp:0x4=0xf0000000 off



[Notes]
Following error may occur when downloading or performing step if you did not issue the command even though you are using Vivado 2014.1 or later.
¡¡ ICE Error No.f56: Sticky over run error.