Question:When using the extended format of CAN ID, the programmer setting and the ID value obtained by the protocol analyzer are different.

The extended format of CAN ID is 29 bit, which is the same as the 11bit base ID (similar to the 11bit when using the standard format) and the 18bit extended ID.

The setting in NETIMPRESS is specified in the order of extended ID (18bit) followed with base ID (11bit), but in the logger, it is displayed in the order of base ID (11bit) followed with extended ID (18bit), so the setting value and display Will be different. When setting the ID in NETIMPRESS, consider the arrangement of extended ID and base ID.

 