Question:How to set the LockBit / OTP function of FR830 with remote software (AZ490)

LockBit/OTP settings can be changed by changing the value at address 0C0 in Parameter Table 2.



Address :#0C0
 00:Disable LockBit/OTP 設定を有効にしない
 01:Enable LockBit
 02:Enable OTP

*The most significant bit of address 0C0 is set to disable serial programming, so the setting value when disabling serial programming is 80 to 82.

*When you access the Parameter Table 2 screen, you will be asked to enter the password. Enter "AF200".



*When you change the setting value on the Parameter Table 2 screen, click the [OK] button on the right end of the screen to reflect the setting value on the writer.


 