Question:"CM UNDEFINED" is displayed on the LCD, but what is this?

When CM UNDEFINED is displayed, there are the following cases.


1. YIM folder is not selected.

Select the folder. ([Select] button on Remote Controller File Operation tab).
In case of standalone operation, perform the key operation as follows.

[FUNC][B][0] + [up] or [down] + [SET][FUNC][SET][SET]


*If using only one YIM folder, when FUNC B5(holding setting of the current YIM folder)
is set to "SAVE", There is no need to execute FUNC B0(folder selection) after the power is turned on.

Manual reference item
NETIMPRESS Instruction Manual section 5.5.1
AZ490 Instruction Manual section 2-7
AZ490 Instruction Manual section 5-2-5
AZ490 Instruction Manual section 5-5-1
NETIMPRESS Instruction Manual section 5.5.6

2.The definition file is not downloaded to the selected YIM folder.

Please download the definition file by [Load Definition Program] and download the parameter file
suitable for your microcomputer in [Load Paramater].

Manual reference item
Startup Manual section 8-9
AZ490 Instruction Manual section 2-7
AZ490 Instruction Manual section 5-2-4

 