Can NETIMPRESS avant write to multiple microcontrollers simultaneously?

NETIMPRESS avant (AFX100) can be connected with two probes.
Two probes cannot be operated simultaneously.
  When writing to multiple microcomputers at the same time, even if the target microcomputer is the same type, multiple programmers (same number as the number of microcomputers) are required.
  If the number of units increases, use NETIMPRESS acorde to facilitate installation on the writing equipment.

When writing to the board on which the main microcomputer and sub microcomputer are mounted on the same board at the same time, it is necessary that the reset line of each microcomputer is independent.