NETIMPRESS avant / acorde Support

How to change WDT(Watchdog pulse) output mode(Model:FRX821, FRX822, FRX830))

The WDT output mode can be changed by changing the value of 0CF address in Parameter Table 2.



address 0CF:bit 6 □■□□□□□□
bit6=0 :Output while programming (while /TICS output period)
bit6=1 :Always output
*Since you will be prompted to enter a password when accessing the screen of Parameter Table 2, please input "AF200".



*When changing the setting value on the screen of Parameter Table 2, please press the [OK] button at the right end of the screen to reflect the set value on the programmer.

update date:2021/08/11

 

Please cooperate with questionnaire cooperation

Was this answer stood to the visitor's role?

 

           

return to a page