"CM UNDEFINED" is displayed on the second line (MCU TYPE) of the LCD after startup.

If CM UNDEFINED is displayed, it may be as follows.

(1) YIM folder is not selected
(When YIM NOT SELECT is displayed on the first line of the LCD)

-> Select the YIM folder (Select YIM Folder).
For stand-alone operation, execute FOLDER SELECT on the menu Page2.

* If the YIM folder has not been created, create it by referring to Chapter 4.3 and later of the NETIMPRESS avant Startup Manual.
* If the FOLDER SAVE (setting to save the current YIM folder information) on Page 2 of the menu is set to "SAVE", the YIM folder that was selected when the power was turned off will be selected at startup.

(2) The definition program file is not loaded in the selected YIM folder.

-> Load the definition program file with [Load Definition Program] of the remote software (SWX600), and load the parameter file of the MicomPack suitable for the micro you are using with [Load Paramater].

* For details on the procedure, refer to Chapter 4.4 and later of the NETIMPRESS avant Startup Manual.