How to change the reset control after writing in FYX801-S1.

The reset (/TRES) control after completion of writing can be changed by changing the value of 0CF address in Parameter Table 2.




address 0CF:bit 5-4 □□■■□□□□
01:It ends with Hi-Z. The flash writing mode is continued and the user application does not operate
1x:Low output after completion of writing

*Since you will be prompted to enter a password when accessing the screen of Parameter Table 2, please input "AF200".


*When changing the setting value on the screen of Parameter Table 2, please press the [OK] button at the right end of the screen to reflect the set value on the programmer.

update date:2023/10/17

 