[Error]No counter resources of ETM available.
[Scope]
ARM
[Error message]
ICE Error No.f1c: No counter resources of ETM available.
Check ETM resources status with the Config. tab of the ETM Control dialog box.
[Cause]
This error is output when the MPU you are using used the counter resources exceeding the limit.
[Workaround]
- Choose [MPU]-[ETM Control] from the menu bar of the microVIEW-PLUS.
Check the number listed for Counter on the [Config.] tab.
Then, choose [MPU]-[Trace Enable/ETM Setup] from the menu bar of the microVIEW-PLUS.
Check the number of items that are set up with 2 for Count on the [Trigger], [Sequencer] and [Ext. Output] tabs.
Make sure that this number does not exceed the number listed for Counter on the Config. tab.