adviceLUNA II Support
[Error]ETM type setup error
[Scope]
ARM ETM
[Error message]
ICE Error No.f0a: ETM type setup error
[Cause]
This error is output when ETM type is incorrectly specified.
[Workaround]
Choose [MPU]-[ETM Control] from the menu bar of the microVIEW-PLUS.
Specify ETM type on the Control tab.
For details, see Section 13.1.4 "InitialSetting 1 (ETM Control Setting)".
ARM ETM
[Error message]
ICE Error No.f0a: ETM type setup error
[Cause]
This error is output when ETM type is incorrectly specified.
[Workaround]
Choose [MPU]-[ETM Control] from the menu bar of the microVIEW-PLUS.
Specify ETM type on the Control tab.
For details, see Section 13.1.4 "InitialSetting 1 (ETM Control Setting)".
Please cooperate questionaire cooperation
Was this answer stood to the visitor's role?