[Error]Monitor Point data control error.
[Scope]
ARM
[Error message]
ICE Error No.fef: Monitor Point data control error.
[Cause]
This error is output when Monitor point ends up in a failure.
It does not occur in normal use, but it occurs when the power supply, clock, etc. of the user system are unstable.
[Workaround]
Check the user system power supply, clock, and JTAG/SWD signal.
ARM
[Error message]
ICE Error No.fef: Monitor Point data control error.
[Cause]
This error is output when Monitor point ends up in a failure.
It does not occur in normal use, but it occurs when the power supply, clock, etc. of the user system are unstable.
[Workaround]
Check the user system power supply, clock, and JTAG/SWD signal.