Question:How to write multiple objects using external Key (EXE keys)

To write multiple objects using external key (EXE keys), you can switch between the two environments by writing the following in CSB file description.

LK1,02,FB0(TEST1.YIM),DF;Select TEST1.YIM / Execute EPR
LK2,02,FB0(TEST2.YIM),DF;Select TEST2.YIM / Execute EPR



If you want to rewrite by changing more than three folders, if you omit the folder name on FB0 as below, folders are switched one by one each time EXE1 key is pressed.

LK1,01,FB0;Change YIM
LK2,01,DF;Execute EPR

In this case, it is necessary to change the MCU Type (comment displayed at the top of the LCD) in Parameter Table 1 for each folder so that you can see what folder is currently selected.

* NETIMPRESS next allows you to write up to 32 kinds of data by using Script0 to Script4 of Digital I/O. Please use a bar code reader when it is necessary to write more type of data.

 

Please cooperate with questionnaire cooperation

Was this answer stood to the visitor's role?

 

           