Question:How to change the reset control after writing (in FS718,FS719,FS720,FS728,FS818,FS819,FS828)

The reset (/TRES) control after completion of writing can be changed by changing the value of 0CF address in Parameter Table 2.



address 0C1:bit 4,5 □□■■□□□□



A Mode:It ends with Hi-Z. The flash writing mode is continued and the user application does not operate
B Mode:After the device function is completed, assert reset for a certain period (100ms) to operate the user application
Standard:Low output after completion of writing

*Since you will be prompted to enter a password when accessing the screen of Parameter Table 2, please input "AF200".


*When changing the setting value on the screen of Parameter Table 2, please press the [OK] button at the right end of the screen to reflect the set value on the programmer.

 

Please cooperate with questionnaire cooperation

Was this answer stood to the visitor's role?

 

           

return to a page